Recharging Batteries

Navigation

  • The unit must be in a low background area with no radioactive sources present.
  • To power up the instrument, press and hold the ON/OFF button until the red and blue LEDs illuminate.

Figure 1. Plugging-in the cable.

  • Do not rotate the LEMO Series K connector. It is a plug, not a screw.
  • To remove the cable grab the connector (not the cable) and pull.
  • Do not pull at the cable behind the connector (Figure 2). You must unlatch the connector by grabbing it in order to remove it.

Figure 2. Unlatching and removing the connector.

Do not forget to re-insert the bung.

Accessories for the FLIR identiFINDER R400

This section gives an overview of the various accessories available for the FLIR identiFINDER R400; some are included with certain variants, others are sold seperately.

FLIR powerPACK 2

The FLIR powerPACK 2 is a container for 4 standard AA batteries. A FLIR powerPACK 2 with disposable batteries is an excellent backup if you need to be ready at a momment's notice.

  • Do not charge batteries in the FLIR powerPACK 2.
  • Remove the AA cells if you do not plan on using the instrument for a long period of time.

To install batteries in the FLIR powerPACK 2

1. Use a Phillips PH1 screwdriver to remove the screw.

2. Separate the halves of the FLIR powerPACK 2.

3. Hold the half with the contacts in one hand and insert the 4 AA-size batteries.

> Observe the polarity. The correct orientation is shown on the label.

4. Slide the other half of the FLIR powerPACK 2 over the batteries.

> Observe the indent to determine the correct orientation.

5. Insert the screw and tighten it.